Overview
This analyser implements the dynamic loudness model of Chalupper and Fastl (2002), as well as the loudness fluctuation model of Chalupper (2000). These models use the Bark critical band rate scale to model auditory filters, and auditory temporal integration is included in the loudness model. Zwicker and Fastl’s (1999) sharpness model is applied to the output of the loudness model.
Outputs
Verification
The loudness of a 1 kHz tone with a sound pressure level of 40 dB is 1 sone.
Code Authors
The code for this analyser was provided by Josef Chalupper, and adapted for PsySound3 by the PsySound3 team.
Key References
J. Chalupper and H. Fastl (2002) "Dynamic Loudness Model (DLM) for Normal and Hearing-Impaired Listeners," Acta Acustica United with Acustica, vol. 88, pp. 378-386.
J. Chalupper (2000) "Modellierung der Lautstärkeschwankung für Normal- und Schwerhörige," in DAGA 2000, pp. 254-255.
E. Zwicker and H. Fastl (1999) Psychoacoustics: Facts and Models. Berlin; New York: Springer.